DuPont™ Tyvek® Supro/Supro Plus Tyvek® Pro

Building Solutions | DuPont™ Tyvek® Homewrap®
 
 
 
Product

DuPont™ Tyvek® Supro Roof Underlay

Drawing from more than 20 years of international manufacturing experience in the field of construction, DuPont™ Tyvek® Supro is a roof underlay that has been proven worldwide to be durable and to perform in extreme environments.

 
 
 
 
 
 

Additional Information

CodeMark Tyvek® Supro (PDF)

CodeMark Tyvek® Supro Metal (PDF)

MSDS Tyvek® Supro (PDF)

Tyvek® Supro Technical Bulletin (PDF)

Tyvek® Technical Guide - Roof (PDF)

MSDS File - DuPont™ Tyvek® for use in building construction (PDF)

Air Vapour Control guidelines

 
 
 

DuPont™ Tyvek® Supro Roof Underlay

An underlay is a key component of the roofing structure, and provides an important element in the weather tightness of a roof cladding system. The underlay acts as a secondary barrier to water ingress from the external environment while also helping to control internally generated moisture. Their function in terms of building durability is important and their on-going performance needs to be preserved to guarantee the life of the building

 
 
 
 
 
 

Features & benefits

Feature Benefit
Unique flash spun HDPE patented product with absorbent and anti-slip non-woven top layer
  • Durability
  • High Tensile strength and lightweight
  • Excellent Water Hold-out
  • Total building envelope system
  • High Water Vapour Permeability
  • Supro plus – integrated tape
  • Easy install and lap taping
  • Unique flash spun HDPE patented product with absorbent and anti-slip non-woven top layer
  • Suitable from Arizona to Artic weather conditions
  •  
     
     

    Physical Properties - Tyvek® Supro

    Method Unit Value
    NZ Building Code E2/AS1 & NZS2295:2006 Test Method Requirement Dupont™Tyvek® Supro® (2507B)
    3.2.1 Surface Absorbency AS/NZS4201:6 ≥150gsm CodeMark CMA-CM40146
    3.2.2 Water Resistance AS/NZS4201:4 100mm/24hrs pass
    Water Vapour Resistance ASTM E96-B < 7Mn.s/g <0.3Mn.s/g
    3.2.4 pH Extract AS/NZS 1301.412S 5.5-8.0 pass
    3.2.5 Mechanical Strength - -
    Edge Tear (MD & CD) TAPPI T470 70N & 55N 305N & 254N
    Synthetic Tensile (MD & CD) NZS/AS 1301:448S 3.9kN/m & 2.8kN/m 6.3kN/m & 5.0kN/m
    3.2.6 Flammability NZS/AS 1530.2 ≤ 5 pass
    Resistance to UV / Weather Exposure ASTM G154 ≥ 85% strength/7days pass
    2.3.2 Absorbency Type R1/R2 CodeMark CMA-CM40146
    Wind Speed - Extra High (on RAB) pass
    Weight / Size - - 145gsm / 1500mm
     
     
     

    Physical Properties - Tyvek® Pro

    Method Unit Value
    NZ Building Code E2/AS1 & NZS2295:2006 Test Method Requirement Dupont™ Tyvek® Pro® (2508B)
    3.2.1 Surface Absorbency AS/NZS4201:6 ≥150gsm CodeMark CMA-CM40146
    3.2.2 Water Resistance AS/NZS4201:4 100mm/24hrs pass
    Water Vapour Resistance ASTM E96-B < 7Mn.s/g <0.5Mn.s/g
    3.2.4 pH Extract AS/NZS 1301.412S 5.5-8.0 pass
    3.2.5 Mechanical Strength - -
    Edge Tear (MD & CD) TAPPI T470 150N & 130N 255N & 270N
    Synthetic Tensile (MD & CD) NZS/AS 1301:448S 3.0kN/m & 2.5kN/m 5.1kN/m & 4.3kN/m
    3.2.6 Flammability NZS/AS 1530.2 ≤ 5 pass
    Resistance to UV / Weather Exposure ASTM G154 ≥ 85% strength/7days pass
    2.3.2 Absorbency Type R1/R2 CodeMark CMA-CM40146
    Wind Speed - Extra High (on RAB) pass
    Weight / Size - - 125gsm / 1500mm